Pinto, Eduardo Costa’s team published research in Rapid Communications in Mass Spectrometry in 33 | CAS: 20880-92-6

Rapid Communications in Mass Spectrometry published new progress about 20880-92-6. 20880-92-6 belongs to alcohols-buliding-blocks, auxiliary class Other Aliphatic Heterocyclic,Chiral,Alcohol, name is ((3aS,5aR,8aR,8bS)-2,2,7,7-Tetramethyltetrahydro-3aH-bis([1,3]dioxolo)[4,5-b:4′,5′-d]pyran-3a-yl)methanol, and the molecular formula is C12H20O6, HPLC of Formula: 20880-92-6.

Pinto, Eduardo Costa published the artcileSensitive detection of topiramate degradation products by high-performance liquid chromatography/electrospray ionization mass spectrometry using ion-pairing reagents and polarity switching, HPLC of Formula: 20880-92-6, the publication is Rapid Communications in Mass Spectrometry (2019), 33(1), 116-124, database is CAplus and MEDLINE.

Rationale : The chromatog. anal. of topiramate and its degradation products is challenging due to the absence of chromophoric moieties in their structures, the wide polarity range of the compounds and their ionization differences. This work proposes two new mass spectrometry approaches for evaluating these analytes. Methods : Based on the calculated exptl. limit of detection (LOD), a highly sensitive high-performance liquid chromatog. (HPLC) paired-ion electrospray ionization mass spectrometry (PIESI-MS) method was developed for the determination of topiramate inorganic degradation products. The influence of different solvent systems on the LODs for topiramate and its main degradation products was determined in both pos./neg. ionization modes. In addition, a HPLC method to analyze both organic and inorganic degradation products was proposed by mass spectrometry with pos./neg. ion switching electrospray ionization. Results : A sensitive HPLC/PIESI-MS method was achieved for the efficient separation of topiramate inorganic degradation products. Both sulfate and sulfamate were detected in the pos. selected ion monitoring (SIM) mode with an increased sensitivity compared with the neg. SIM mode. The HPLC/ESI-MS anal. with pos./neg. ion switching allowed the simultaneous separation and detection of the major degradation products of topiramate in a 10-min run using a single column and a single detector. Conclusions : Two new alternative MS approaches for analyzing the main degradation products of topiramate were developed. The proposed methods are considered advantageous over the existing methods and can be applied to quality control studies of topiramate.

Rapid Communications in Mass Spectrometry published new progress about 20880-92-6. 20880-92-6 belongs to alcohols-buliding-blocks, auxiliary class Other Aliphatic Heterocyclic,Chiral,Alcohol, name is ((3aS,5aR,8aR,8bS)-2,2,7,7-Tetramethyltetrahydro-3aH-bis([1,3]dioxolo)[4,5-b:4′,5′-d]pyran-3a-yl)methanol, and the molecular formula is C12H20O6, HPLC of Formula: 20880-92-6.

Referemce:
https://en.wikipedia.org/wiki/Alcohol,
Alcohols – Chemistry LibreTexts